| Russian Journal | ISSN 0042-8809 |
| Voprosy Meditsinskoi Khimii | Biomedical Chemistry |
Issue:
Volume 48, issue 6
Title: DETERMINATION OF FUNCTIONAL ACTIVITY OF COMPONENTS AND
FACTORS OF THE HUMAN COMPLEMENT
Authors: L.V.Kozlov
Address: G.N.Gabrichevsky
Moscow scientific research institute of epidemiology and microbiology, 125212 Moscow,
street of Admiral Makarova, 10, a fax (095)452-18-30
Abstract:
Development suitable for clinical
researches of hemolytic methods of determination of functional activity of the first
components of a complement has allowed to show diagnostic value of testing activity of
complement components in comparison with their contents as antigens. It has predetermined
necessity for building modern ELISA tests-systems for quantitative determination of
functional activity of complement components. Such methods built for the first time allow
to determine activity of components C1q, C2,
C3, C4 (and a ratio of isotypes C4A and C4B), C1 - inhibitor,
factors B and D. Addition of these tests-systems ELISA systems for quantitative
determination of components, and in case of Ñ1-inhibitor of presence IgG, IgA and IgM autoantibodies
against Ñ1-inhibitor frames
opportunities of an evaluation complement status of the patient, hereditary predisposition
to such diseases as a stomach ulcer, the glaucoma, a clamidiosis, bacteroidosis, allows to
carry out differential diagnostics of angioedema. Inhibition of covalent linkage C4b or
C3b various endogenic and exogenous effectors during formation Ñ3-and Ñ5-convertases allows to understand processes of a
regulation of a homeostasis, and also the mechanism of action of drugs.
Key words: complement system, functional activity of components, hemolytic methods, ELISA, C1q, C2, C3, C4, factor B, factor D, C1 inhibitor.
[Back]